02.120.0212 Pipe column in masonry wall

02.120.0212 Pipe column in masonry wall

International Masonry Institute
This detail shows a steel pipe column in a concrete masonry wall. Open ended concrete masonry units are used around the column. The column bears on a bearing plate with drypack underneath for leveling, if required, anchored to the footing. Dowels at intervals as desgined run perpendicular to the masonry, and the concrete slab is thickened below the masonry wall. This detail as shown is intended to illustrate a general concept or method of construction. Details that show different or modified concepts or methods can be of equal validity and should not be excluded from consideration. this detail shall not be used for construction without the approval an signature of a licensed design professional. The person using this detail shall be responsible for its complete design and proper application.
Default Title